{"title":"8 AWG PV Wire 2000V UL4703 | Copper Solar Cable | Made in USA","description":"\u003ch3 style=\"font-size:18px;font-weight:600;margin:0 0 10px;\"\u003e8 AWG PV Wire 2000V UL4703 — Made in USA | In Stock | Ships Same Day\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003ePhotovoltaic Cable LLC offers UL4703-certified 8 AWG Copper PV Wire rated at 2,000 Volts — the preferred size for string-to-combiner connections, medium and long DC runs, and commercial rooftop installations where higher current capacity is required. Available in Black and Red, in 500 ft and 2,500 ft reels. All inventory ships same day from our three U.S. fulfillment centers.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eWhy choose 8 AWG over 10 AWG\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003e8 AWG carries up to 40A continuous DC current — significantly more than 10 AWG — making it the right choice when your string current exceeds 30A, when runs exceed 100 ft, or when you need to minimize voltage drop in longer DC feeder runs. It is also commonly specified for combiner box to inverter connections in commercial and ground-mount systems. Use our \u003ca href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\" style=\"color:#0066cc;text-decoration:underline;\"\u003eVoltage Loss Calculator\u003c\/a\u003e to determine if 8 AWG is the right gauge for your project.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 20px;font-size:14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;width:40%;\"\u003eConductor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e19-strand copper per ASTM B-3, B-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eVoltage rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e2,000 Volts (2kV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUL 4703 — RHW-2 (UL 44) — USE-2 (UL 854)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eCross-Linked Polyethylene (XLPE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eTemperature rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e−40°C to +90°C (wet and dry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eColors\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eBlack — Red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eReel sizes\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e500 — 2,500 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eUV resistance\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes — sunlight and ozone resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRoHS — Gasoline and Oil Resistant II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eNEC compliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eArticle 690 — grounded and ungrounded PV systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eDirect burial\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes — rated for direct burial, conduit, and free-air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eManufactured in North America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eAvailable configurations\u003c\/h3\u003e\n\u003cul style=\"margin:0 0 20px;padding-left:20px;line-height:2;\"\u003e\n\u003cli\u003e8 AWG 2000V Black — 500 ft reel\u003c\/li\u003e\n\u003cli\u003e8 AWG 2000V Black — 2,500 ft reel\u003c\/li\u003e\n\u003cli\u003e8 AWG 2000V Red — 500 ft reel\u003c\/li\u003e\n\u003cli\u003e8 AWG 2000V Red — 2,500 ft reel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eRecommended applications\u003c\/h3\u003e\n\u003cul style=\"margin:0 0 20px;padding-left:20px;line-height:2;\"\u003e\n\u003cli\u003eString-to-combiner box connections with high string currents\u003c\/li\u003e\n\u003cli\u003eCombiner box to inverter DC feeder runs\u003c\/li\u003e\n\u003cli\u003eMedium and long DC runs where voltage drop must be minimized\u003c\/li\u003e\n\u003cli\u003eCommercial rooftop and ground-mount solar arrays\u003c\/li\u003e\n\u003cli\u003eBoth grounded and ungrounded PV systems per NEC Article 690\u003c\/li\u003e\n\u003cli\u003eDirect burial, conduit, and free-air installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eNot sure if 8 AWG is right for your system?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003eUse our free \u003ca href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\" style=\"color:#0066cc;text-decoration:underline;\"\u003eVoltage Loss Calculator\u003c\/a\u003e to determine the correct gauge and reel length based on your string current, run distance, and acceptable voltage drop.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eShipping \u0026amp; availability\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003eAll 4 configurations are in stock and ship same day from three U.S. fulfillment centers: LaPorte, Texas — Miami Lakes, Florida — Rancho Dominguez, California. Pick-up available at all locations. Most orders arrive within 1–3 business days. Free shipping on orders over $10,000 — applied automatically at checkout.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003e\u003cstrong\u003eWhen should I use 8 AWG instead of 10 AWG?\u003c\/strong\u003e\u003cbr\u003eUse 8 AWG when your string current exceeds 30A, when your DC run exceeds 100 ft, or when your voltage drop calculation requires a larger conductor. Our \u003ca href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\" style=\"color:#0066cc;text-decoration:underline;\"\u003eVoltage Loss Calculator\u003c\/a\u003e will confirm the right gauge for your project.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003e\u003cstrong\u003eIs this wire rated for direct burial?\u003c\/strong\u003e\u003cbr\u003eYes. UL4703-listed PV wire is rated for direct burial, conduit, and free-air installation per NEC Article 690 guidelines.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003e\u003cstrong\u003eDo you offer 1,000 ft reels in 8 AWG?\u003c\/strong\u003e\u003cbr\u003eCurrently available in 500 ft and 2,500 ft reels. Contact our sales team at +1 305 842-6291 to discuss availability for other quantities.\u003c\/p\u003e\n\u003cp style=\"margin:0;color:#555;\"\u003eQuestions about sizing or volume pricing? Call \u003cstrong\u003e+1 305 842-6291\u003c\/strong\u003e or email \u003cstrong\u003esales@photovoltaiccable.com\u003c\/strong\u003e\u003c\/p\u003e","products":[{"product_id":"8-awg-pv-wire-2000v-ul4703-500ft-black","title":"8 AWG PV Wire 2000V UL4703 – 500ft Black | Made in USA","description":"\u003ch3 style=\"font-size:18px;font-weight:600;margin:0 0 10px;\"\u003e8 AWG PV Wire 2000V UL4703 – 500ft Black | Made in USA | In Stock\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003eThis UL4703-certified 8 AWG copper PV wire, 2000V rated, is available in a 500 ft black reel — manufactured in the USA. The 500 ft format is ideal for commercial rooftop installations and string-to-combiner connections where higher current capacity is required than 10 AWG provides.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 20px;font-size:14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;width:40%;\"\u003eConductor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e8 AWG stranded copper per ASTM B-3, B-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eVoltage rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e2,000 Volts (2kV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUL 4703 — RHW-2 (UL 44) — USE-2 (UL 854)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eCross-Linked Polyethylene (XLPE) — UV resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eTemperature rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e−40°C to +90°C (wet and dry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eReel length\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e500 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eNEC compliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eArticle 690 — grounded and ungrounded PV systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eDirect burial\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes — conduit, free-air, and direct burial rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRoHS — Gasoline and Oil Resistant II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:600;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eMade in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eWhen to choose 8 AWG over 10 AWG\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003eUse 8 AWG when your string current exceeds 30A, your DC run exceeds 100 ft, or your voltage drop calculation requires a lower-resistance conductor. Use our \u003ca href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\" style=\"color:#0066cc;text-decoration:underline;\"\u003eVoltage Loss Calculator\u003c\/a\u003e to confirm the right gauge for your project.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eRecommended applications\u003c\/h3\u003e\n\u003cul style=\"margin:0 0 20px;padding-left:20px;line-height:2;\"\u003e\n\u003cli\u003eString-to-combiner box connections with high string currents\u003c\/li\u003e\n\u003cli\u003eCombiner box to inverter DC feeder runs\u003c\/li\u003e\n\u003cli\u003eCommercial rooftop and ground-mount solar arrays\u003c\/li\u003e\n\u003cli\u003eDC runs exceeding 100 ft where voltage drop must be minimized\u003c\/li\u003e\n\u003cli\u003eBoth grounded and ungrounded PV systems per NEC Article 690\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eNeed a different size or color?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003eAlso available in \u003ca href=\"https:\/\/www.photovoltaiccable.com\/products\/8-awg-pv-wire-2000v-ul4703-500ft-red\" style=\"color:#0066cc;text-decoration:underline;\"\u003e500 ft Red\u003c\/a\u003e. For larger reels see \u003ca href=\"https:\/\/www.photovoltaiccable.com\/products\/8-awg-pv-wire-2000v-ul4703-2500ft-black\" style=\"color:#0066cc;text-decoration:underline;\"\u003e2,500 ft Black\u003c\/a\u003e. Browse all sizes in the \u003ca href=\"https:\/\/www.photovoltaiccable.com\/collections\/pv-wire-8-awg-2000-volts\" style=\"color:#0066cc;text-decoration:underline;\"\u003e8 AWG PV Wire 2000V collection\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eShipping \u0026amp; availability\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003eIn stock and ships same day from our fulfillment centers in LaPorte, Texas and Rancho Dominguez, California. Most orders arrive within 1–3 business days. Free shipping applies automatically on orders over $10,000 USD.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:16px;font-weight:600;margin:0 0 8px;\"\u003eResources\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/files\/Technical_Sheet_Photovoltaic_Cable_2000_Volts_UL_4703.pdf?v=1772483774\" style=\"color:#0066cc;text-decoration:underline;\"\u003eTechnical Sheet — PV Wire 2000V UL4703 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0 0 20px;\"\u003e\u003ca href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\" style=\"color:#0066cc;text-decoration:underline;\"\u003eVoltage Loss Calculator\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0;color:#555;\"\u003eQuestions? Call \u003cstrong\u003e+1 305 842-6291\u003c\/strong\u003e or email \u003cstrong\u003esales@photovoltaiccable.com\u003c\/strong\u003e\u003c\/p\u003e","brand":"Photovoltaiccable.com","offers":[{"title":"Black","offer_id":46560573522105,"sku":"PVCU2KV8BK-AHX2","price":428.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/products\/PV-wire-10-AWG-Black-500-feet_d3c54953-9991-438a-bbe6-250e605d32ff.jpg?v=1772766060"},{"product_id":"8-awg-pv-wire-2000v-ul4703-2500ft-black","title":"8 AWG PV Wire 2000V UL4703 – 2500ft Black | Made in USA","description":"\u003ch3 style=\"font-size: 18px; font-weight: 600; margin: 0 0 10px;\"\u003e8 AWG PV Wire 2000V UL4703 – 2,500ft Black | Made in USA | In Stock\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eThis UL4703-certified 8 AWG copper PV wire, 2000V rated, is available in a 2,500 ft continuous black reel — manufactured in the USA. The 2,500 ft format is the largest reel available for 8 AWG, designed for commercial ground-mount arrays and long DC feeder runs where higher current capacity and minimal splicing are both required.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 0 0 20px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600; width: 40%;\"\u003eConductor\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e8 AWG stranded copper per ASTM B-3, B-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eVoltage rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e2,000 Volts (2kV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eUL 4703 — RHW-2 (UL 44) — USE-2 (UL 854)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eCross-Linked Polyethylene (XLPE) — UV resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eTemperature rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e−40°C to +90°C (wet and dry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eReel length\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e2,500 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eNEC compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eArticle 690 — grounded and ungrounded PV systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eDirect burial\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eYes — conduit, free-air, and direct burial rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eRoHS — Gasoline and Oil Resistant II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eMade in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eWhen to choose 8 AWG over 10 AWG\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eUse 8 AWG when your string current exceeds 30A, your DC run exceeds 100 ft, or your voltage drop calculation requires a lower-resistance conductor. Use our \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\"\u003eVoltage Loss Calculator\u003c\/a\u003e to confirm the right gauge for your project.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eRecommended applications\u003c\/h3\u003e\n\u003cul style=\"margin: 0 0 20px; padding-left: 20px; line-height: 2;\"\u003e\n\u003cli\u003eCommercial ground-mount arrays with long DC feeder runs\u003c\/li\u003e\n\u003cli\u003eString-to-combiner box connections with high string currents\u003c\/li\u003e\n\u003cli\u003eCombiner box to inverter feeder runs on large commercial systems\u003c\/li\u003e\n\u003cli\u003eEPC contractor projects requiring large reel formats\u003c\/li\u003e\n\u003cli\u003eBoth grounded and ungrounded PV systems per NEC Article 690\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eNeed a different size or color?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eAlso available in \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/products\/8-awg-pv-wire-2000v-ul4703-2500ft-red\"\u003e2,500 ft Red\u003c\/a\u003e. For smaller reels see \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/products\/8-awg-pv-wire-2000v-ul4703-500ft-black\"\u003e500 ft Black\u003c\/a\u003e. Browse all sizes in the \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/collections\/pv-wire-8-awg-2000-volts\"\u003e8 AWG PV Wire 2000V collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eShipping \u0026amp; availability\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eIn stock and ships same day from our fulfillment centers in LaPorte, Texas and Rancho Dominguez, California. Most orders arrive within 1–3 business days. Free shipping applies automatically on orders over $15,000 USD.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eResources\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/files\/Technical_Sheet_Photovoltaic_Cable_2000_Volts_UL_4703.pdf?v=1772483774\"\u003eTechnical Sheet — PV Wire 2000V UL4703 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003e\u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\"\u003eVoltage Loss Calculator\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; color: #555;\"\u003eQuestions? Call \u003cstrong\u003e+1 \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e305 3564044\u003c\/span\u003e\u003c\/strong\u003e or email \u003cstrong\u003esales@photovoltaiccable.com\u003c\/strong\u003e\u003c\/p\u003e","brand":"Photovoltaiccable.com","offers":[{"title":"Black","offer_id":46566496796857,"sku":"PVCU2KV8BK-AHX6","price":1664.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/files\/PV-Wire-8-AWG-2000-Volts-2500-Feet-Black_642111e5-7e46-4252-88aa-c8c65ed9ae62.jpg?v=1772766060"},{"product_id":"8-awg-pv-wire-2000v-ul4703-500ft-red","title":"8 AWG PV Wire 2000V UL4703 – 500ft Red | Made in USA","description":"\u003ch3 style=\"font-size: 18px; font-weight: 600; margin: 0 0 10px;\"\u003e8 AWG PV Wire 2000V UL4703 – 500ft Red | Made in USA | In Stock\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eThis UL4703-certified 8 AWG copper PV wire, 2000V rated, is available in a 500 ft red reel — manufactured in the USA. The 500 ft format is ideal for commercial rooftop installations and string-to-combiner connections where higher current capacity is required than 10 AWG provides.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 0 0 20px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600; width: 40%;\"\u003eConductor\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e8 AWG stranded copper per ASTM B-3, B-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eVoltage rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e2,000 Volts (2kV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eUL 4703 — RHW-2 (UL 44) — USE-2 (UL 854)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eCross-Linked Polyethylene (XLPE) — UV resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eTemperature rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e−40°C to +90°C (wet and dry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eReel length\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e500 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eNEC compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eArticle 690 — grounded and ungrounded PV systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eDirect burial\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eYes — conduit, free-air, and direct burial rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eRoHS — Gasoline and Oil Resistant II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eMade in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eWhen to choose 8 AWG over 10 AWG\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eUse 8 AWG when your string current exceeds 30A, your DC run exceeds 100 ft, or your voltage drop calculation requires a lower-resistance conductor. Use our \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\"\u003eVoltage Loss Calculator\u003c\/a\u003e to confirm the right gauge for your project.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eRecommended applications\u003c\/h3\u003e\n\u003cul style=\"margin: 0 0 20px; padding-left: 20px; line-height: 2;\"\u003e\n\u003cli\u003eString-to-combiner box connections with high string currents\u003c\/li\u003e\n\u003cli\u003eCombiner box to inverter DC feeder runs\u003c\/li\u003e\n\u003cli\u003eCommercial rooftop and ground-mount solar arrays\u003c\/li\u003e\n\u003cli\u003eDC runs exceeding 100 ft where voltage drop must be minimized\u003c\/li\u003e\n\u003cli\u003eBoth grounded and ungrounded PV systems per NEC Article 690\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eNeed a different size or color?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eAlso available in \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/products\/8-awg-pv-wire-2000v-ul4703-500ft-black\"\u003e500 ft Black\u003c\/a\u003e. For larger reels see \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/products\/8-awg-pv-wire-2000v-ul4703-2500ft-red\"\u003e2,500 ft Red\u003c\/a\u003e. Browse all sizes in the \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/collections\/pv-wire-8-awg-2000-volts\"\u003e8 AWG PV Wire 2000V collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eShipping \u0026amp; availability\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eIn stock and ships same day from our fulfillment centers in LaPorte, Texas and Rancho Dominguez, California. Most orders arrive within 1–3 business days. Free shipping applies automatically on orders over $450 USD.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eResources\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/files\/Technical_Sheet_Photovoltaic_Cable_2000_Volts_UL_4703.pdf?v=1772483774\"\u003eTechnical Sheet — PV Wire 2000V UL4703 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003e\u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\"\u003eVoltage Loss Calculator\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; color: #555;\"\u003eQuestions? Call \u003cstrong\u003e+1 \u003cspan\u003e305 3564044\u003c\/span\u003e\u003c\/strong\u003e or email \u003cstrong\u003esales@photovoltaiccable.com\u003c\/strong\u003e\u003c\/p\u003e","brand":"Photovoltaiccable.com","offers":[{"title":"Red","offer_id":46983383089337,"sku":"PVCU2KV8RD-AHX3","price":428.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/files\/PV_Wire_8_Gauge_Red_ecbf9b86-3162-47ac-a3e1-a67b685aa8fb.jpg?v=1772655025"},{"product_id":"8-awg-pv-wire-2000v-ul4703-2500ft-red","title":"8 AWG PV Wire 2000V UL4703 – 2500ft Red | Made in USA","description":"\u003ch3 style=\"font-size: 18px; font-weight: 600; margin: 0 0 10px;\"\u003e8 AWG PV Wire 2000V UL4703 – 2,500ft Red | Made in USA | In Stock\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eThis UL4703-certified 8 AWG copper PV wire, 2000V rated, is available in a 2,500 ft continuous red reel — manufactured in the USA. The 2,500 ft format is the largest reel available for 8 AWG, designed for commercial ground-mount arrays and long DC feeder runs where higher current capacity and minimal splicing are both required.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 0 0 20px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600; width: 40%;\"\u003eConductor\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e8 AWG stranded copper per ASTM B-3, B-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eVoltage rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e2,000 Volts (2kV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eUL 4703 — RHW-2 (UL 44) — USE-2 (UL 854)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eCross-Linked Polyethylene (XLPE) — UV resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eTemperature rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e−40°C to +90°C (wet and dry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eReel length\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003e2,500 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eNEC compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eArticle 690 — grounded and ungrounded PV systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eDirect burial\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eYes — conduit, free-air, and direct burial rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eRoHS — Gasoline and Oil Resistant II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd; font-weight: 600;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid #ddd;\"\u003eMade in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eWhen to choose 8 AWG over 10 AWG\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eUse 8 AWG when your string current exceeds 30A, your DC run exceeds 100 ft, or your voltage drop calculation requires a lower-resistance conductor. Use our \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\"\u003eVoltage Loss Calculator\u003c\/a\u003e to confirm the right gauge for your project.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eRecommended applications\u003c\/h3\u003e\n\u003cul style=\"margin: 0 0 20px; padding-left: 20px; line-height: 2;\"\u003e\n\u003cli\u003eCommercial ground-mount arrays with long DC feeder runs\u003c\/li\u003e\n\u003cli\u003eString-to-combiner box connections with high string currents\u003c\/li\u003e\n\u003cli\u003eCombiner box to inverter feeder runs on large commercial systems\u003c\/li\u003e\n\u003cli\u003eEPC contractor projects requiring large reel formats\u003c\/li\u003e\n\u003cli\u003eBoth grounded and ungrounded PV systems per NEC Article 690\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eNeed a different size or color?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eAlso available in \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/products\/8-awg-pv-wire-2000v-ul4703-2500ft-black\"\u003e2,500 ft Black\u003c\/a\u003e. For smaller reels see \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/products\/8-awg-pv-wire-2000v-ul4703-500ft-red\"\u003e500 ft Red\u003c\/a\u003e. Browse all sizes in the \u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/collections\/pv-wire-8-awg-2000-volts\"\u003e8 AWG PV Wire 2000V collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eShipping \u0026amp; availability\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003eIn stock and ships same day from our fulfillment centers in LaPorte, Texas and Rancho Dominguez, California. Most orders arrive within 1–3 business days. Free shipping applies automatically on orders over $5,000 USD.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: 600; margin: 0 0 8px;\"\u003eResources\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/files\/Technical_Sheet_Photovoltaic_Cable_2000_Volts_UL_4703.pdf?v=1772483774\"\u003eTechnical Sheet — PV Wire 2000V UL4703 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 20px;\"\u003e\u003ca style=\"color: #0066cc; text-decoration: underline;\" href=\"https:\/\/www.photovoltaiccable.com\/pages\/voltage-drop-calculator\"\u003eVoltage Loss Calculator\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; color: #555;\"\u003eQuestions? Call \u003cstrong\u003e+1 \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e305 3564044\u003c\/span\u003e\u003c\/strong\u003e or email \u003cstrong\u003esales@photovoltaiccable.com\u003c\/strong\u003e\u003c\/p\u003e","brand":"Photovoltaiccable.com","offers":[{"title":"Red","offer_id":46983410811065,"sku":"PVCU2KV8RD-AHX7","price":1664.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/files\/PV-Solar-Wire-8-AWG-2000-Volts-2500-Feet-Red.jpg?v=1772655034"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0422\/3824\/7063\/collections\/Photovoltaic_Cable_2500_feet_reel_black.png?v=1685988090","url":"https:\/\/www.photovoltaiccable.com\/collections\/8-awg-pv-wire-2000-volts.oembed","provider":"Photovoltaiccable.com","version":"1.0","type":"link"}